The factors that cause this fault can be analyzed from the following points:
(1) Is the external power supply normal? (2) Is the external switch normal? (3) Can you see the motherboard information when you turn it on? If not, it may be that the motherboard is damaged. Stuck, it may be a program error or motherboard failure or screen damage.
2.There is no response to the buttons of the fusion splicer
The factors that cause this fault can be analyzed from the following points:
(1) Relevant button failure (2) Illegal operation (3) The machine is slow or crashes.
3.The fusion splicer cannot heat the heat shrinkable sleeve
The factors that cause this fault can be analyzed from the following points:
(1) What is the temperature of the heater. Whether the heat is not good. If the heat is enough, there may be a problem with the heat-shrinkable sleeve (2) If the heat is not good, the heater may be damaged; (3) Check whether the power supply of the heater is normal
4.The power supply battery of the fusion splicer cannot supply power
The factors that cause this fault can be analyzed from the following points:
(1) Damaged battery pack (2) Damaged battery charger or damaged charging circuit. (3) Poor charging connection.
5.The fusion splicer cannot pass the self-test
The factors that cause this fault can be analyzed from the following points
(1) If the parts that cannot pass the self-inspection are damaged, deal with the corresponding faults. (2) Make mistakes in the procedure
6.The Splicing Machine crashes during the Splicing process
The factors that cause this fault can be analyzed from the following points:
(1) Program error (2) Poor contact of key components on the surface, or unstable voltage. (3) motherboard failure
7.Optical fiber propulsion failure
The cause of the fault can be analyzed from the following points: (1) The motor fault. (2) V-groove is blocked or cannot clamp fiber.
8.The fusion splicer display cannot be displayed
The cause of the fault can be analyzed from the following points:
(1) Whether the display power supply and data cable are connected properly.
(2) Whether the motherboard information can be seen when booting, if not, the motherboard, is faulty possibly.
(3) If you can see the motherboard information when booting, it is possible that the screen is damaged, or the optical system is failure.
9.The fusion splicer prompts that the fiber cannot be found
The cause of the fault can be analyzed from the following points:
Optical system problem
10.Welding loss is too large
The cause of this failure can be analyzed from the following points:
(1) The end face of the fiber is not clean and dusty, or there is debris on the V-shaped groove, or there is debris on the fiber holder.
(2) The angle difference of cutting end face of fiber is too big.
(3) Problems with the optical system, the objective lens problem leads to estimation errors.
(4) Welding strength is not enough or too strong, discharge position deviation.
(5) Fusion splicer program error.